My RCA 16AP4 had absolutely zero emission. When I collected the set, it had a brightener on the tube. The brightener simply runs the filament at a higher voltage and the extra power is to heat the cathode to bring up emission.

The earlier CRTs like the 16AP4 have fairly substantial cathodes and so I was not worried about rejuvenation. Running the cathode at 8 volts for hours made no change.

The rejuvenation process produces a controlled electrical arc between the grid and cathode to presumably strip the non-emissive and contaminated layer of oxide from the cathode. By a careful use of rejuvenation (one shot) followed by a clean, I brought the tube back up to good emission. It has been consistently good for about six months now and I no longer use or need the brighterner! Do not expect the tube to be as bright as a '60's set but at least now produces a good clean and sharply focussed image on the screen with adequate contrast. I posted some images earlier:

Note the set, an RCA 9TC275 has only 11kV to 12kV Hi-Voltage for the CRT but it is enough to provide a good watchable picture in the living room in the evening.

Remember, over doing the rejuvenation will be lethal. I have detroyed a trinitron tube with rejuvenation: one rejuv shot brought up emission and a foolish second try killed it permanently. I do not think one rejuvenation will hurt the 16AP4. And besides, what else have you to lose?

Looked at the pictures from my earlier thread.
http://videokarma.org/showthread.php?t=251172

I left the tube for six months dormant and when I fired it up again it still worked but emission was down slightly. I simply did a "clean" and it brought the emission up again. I won't be inclined to touch again.

As I mentioned earlier, I believe the tube has some gas (slight whitening of the getter) but it still works okay with no blue purple luminescence in the tube. The evacuation nipple is metal and I would guess that there is a very very slow leak...

Last edited by Penthode; 11-08-2011 at 02:01 PM.
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 12:57 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.