Videokarma.org

Go Back   Videokarma.org TV - Video - Vintage Television & Radio Forums > Early B&W and Projection TV

Notices

We appreciate your help

in keeping this site going.
 
 
Thread Tools Display Modes
Prev Previous Post   Next Post Next
  #11  
Old 07-17-2011, 08:23 PM
old_coot88 old_coot88 is offline
VideoKarma Member
 
Join Date: Sep 2009
Posts: 2,654
Quote:
Originally Posted by vts1134 View Post
...unless I am reading something wrong ALL of my heaters and the "x" lead out of T1 are shorted to ground. The "x" lead from the transformer goes to a terminal strip and is soldered to three leads that run to the heater pins. When I disconnect those leads from each other every one of them reads shorted to ground including the lead from T1.
OK, here's what's going on: you're reading DC resistances so low that they show 'short' on your meter. All those tube heaters in parallel will show very low DC resistance, as will the 6.3V winding. But rest assured there is no short. If there were the tube heaters would not be lighting, and the 3 amp line fuse would blow.

Now on that 12AU7 video tube (V6), both heaters are lighting, right?
Reply With Quote
 