Quote:
Originally Posted by old_coot88
It looks like there are two leads coming out of T1 that go to ground. One is the centertap of the Hv secondary, and the other is the bottom end of the 6.3V secondary (the heater winding). The top of the 6.3V winding is point 'X', and it certainly should not be grounded.
|
There are eight leads coming out of T1. I account for all of them, and unless I am reading something wrong ALL of my heaters and the "x" lead out of T1 are shorted to ground. The "x" lead from the transformer goes to a terminal strip and is soldered to three leads that run to the heater pins. When I disconnect those leads from each other every one of them reads shorted to ground including the lead from T1.
I'm pointing to the location where the leads were soldered together in the picture above. The terminal the right is where the proper ground lead runs to, it's terminal is connected directly to the chassis.
Does that make any sense at all?