Old 07-03-2011, 01:12 PM
DaveWM DaveWM is offline
VideoKarma Member
 
Join Date: Feb 2009
Location: Orlando FL
Posts: 5,607
well something is not right, there should be a jumper before the "long brown resistor, which I am guessing is a 13k screen resistor for the HOT. Any way if the HV pot is not open or shorted and the 1.5 meg resistors are ok, both of which I think you have checked, then the only other thing I can think of is a leaky .01 1kv cap between the grid and the cathode of that tube (pin 1 and 5). IF that cap is leaking then it would throw of the bias of the tube and could cause it to over conduct. NOTE you need to use a .01 1KV (not lower voltage disc) if you choose to replace it.

I cant say forsure this is the problem since you can seem to find a way to check the tube currents (either the 1k or a jumper in the cathode of the 6bk4).

if you can fix your scanner OR get a pic of the chassis around the 6bk4 (including the term strip) them I might be able to figure out how you are supposed to check the shunt current.
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 04:59 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.