Quote:
Originally Posted by vts1134 View Post
I've only had the set on for seconds after noticing the problem so I don't know if the 1X2 is hot to the touch. I could test this theory if you think it's ok to leave the set powered up for that long.
Umm.. considering the rarity and irreplacibility of that flyback, and since you haven't already run it for more than a few seconds in the fault state, please hold off on this test.
Rather (after replacing C61), do the 'air arc' test again. It will confirm whether the fly's putting out without loading it down.

Now, if the fly's putting out, install the 1X2 with the plate cap connected, and remove the doorknob. This will avoid loading the flyback (in case the tube is gassy). If the tube is good, the HV should come up and light the CRT. If the 1X2 is gassy, it may fry the 470K resistor (R89) in series with the HV lead. R89 is thus "sacrificial" and takes the load otherwise borne by the flyback with a gassy 1X2. Much easier to replace a resistor than the flyback.
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 09:44 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.