I assume you don't mean the evacuation tip is broken. If it's intact there's still a chance the 12LP4 is good.
Elves probably started to repair the base for you and got chased away by your Dachshund. Actually, if he did knock it off he did you a favor because it couldn't have been soldered on very well. One method I've read on this forum is to attach small gauge wire to the leads to make it easier to thread the socket back on. John Quote:
|
|
#2
|
|||
|
|||
|
Removing all the solder from the pins on the base is a necessary first step in saving your 12LP4.
If you heat the pins one at a time and then quickly smack the base on your work bench while the solder is still molten, this will effectively remove all the solder from each pin. You should be able to carefully finesse each wire back into the base. Glue the base to the neck making sure each wire is fully inserted in each pin, I use Elmer's. Allow 24 hours for the glue to set. Finally, with the tube face-down, solder each pin, removing your iron the instant the solder starts to flow. Good luck. |
|
#3
|
|||
|
|||
|
I think the T-100 uses a 10BP4, the T-120 uses the 12lp4.
Same base pins. |
|
#4
|
||||
|
||||
|
An easier way to do this is to use some fine wire, like strands from a line cord. Solder a 6 inch length of a strand to the end of each lead coming from the CRT. Make sure the solder joint is small enough to go through the holes in the pins on the base. Now you can easily thread each strand through the appropriate pin. Once all are threaded, put some glue on the base, and pull the base onto the tube and solder each pin. As you do this, you can remove the strand.
|
![]() |