Videokarma.org

Go Back   Videokarma.org TV - Video - Vintage Television & Radio Forums > Diagnostic & Test Equipment

Notices

We appreciate your help

in keeping this site going.
Reply
 
Thread Tools Display Modes
  #1  
Old 01-05-2011, 03:52 PM
JoeNewberry's Avatar
JoeNewberry JoeNewberry is offline
VideoKarma Member
 
Join Date: Nov 2010
Location: Acworth, GA
Posts: 57
The probes are 100MHz, 10x, 10MEG, 7.7pf capacitance.

The variable capacitor on the probe has allowed me to smooth out the curves, but I'm still getting sharp slopes instead of flat peaks. If I'm reading it correctly, it seems like the voltage rises where it should be a steady .5V across.

I've noticed that with no probes attached and the V/div setting at the lowest point, I can see a moderate sine wave. I assumed it was unavoidable background interference, since just getting my hand near the inputs is enough to generate a waveform. Could that small wave be getting added to my test signal and causing this rise?