#1
|
||||
|
||||
|
I pulled the PS chassis out this evening, not only did I not replace the Seleniums I also didn't replace any of the Electrolytics, they held up well though so no regrets there.
One of the cans was replaced with a Sprague at some point, the date code on it is 1964 so I may leave that one alone, I suspect it's the four section that's causing the problem. I'll replace the Lytics on this chassis and see if that fixes it, I'll probably leave the Seleniums in if they're OK, dealing with dropping resistors is a pain in neck. I also need to clean the volume control which is a little flaky and replace the 1/4A Cathode resistor that I jumped with a very fine piece of wire back when I rebuilt it the first time. Last edited by Eric H; 12-04-2010 at 09:07 PM. |
|
#2
|
||||
|
||||
|
There's a couple small mystery's with this set.
First, it has a Tone control knob behind the Vol Control, the control panel isn't marked for a Tone control though. Second, the model tag on the back has been blacked out and a new model # stamped on it, this is a factory mod. The original model is legible under a bright light an was an A-T2288S the new # is -22 B 4309, the B is written in by hand and is barely visible, maybe it means Blond though the set is more of a Maple. Could it be they put the wrong chassis in at the factory or maybe just the wrong model tag, or perhaps a revision with a Tone control added and they just redid the tag by hand? The chassis is a PWR J2. |
|
#3
|
||||
|
||||
|
Quote:
|
|
#4
|
|||
|
|||
|
The 120 at 150 input filter is the first suspect. Next is the first two filter sections before and after the choke. The seleniums may be bad, but they are not the primary cause.
Philco may have sone dumb things, but did not make factory mods/mistakes as described. It is more likely a dealer or used TV shop made two TVs from one. Manufacturing was the best functioning department of all. |
|
#5
|
||||
|
||||
|
It's alive again!
First I tried replacing the 120@150, I had a NOS 1978 dated Twist Lok can that was 300@150, close enough for a filter, but the set still didn't work. It needed to be changed anyhow because it had been leaking and there was corrosion evident on the bottom, sure to fail soon. Next I tried jumping the Selenium's, one at a time but it made no real difference, one made the picture slightly larger but not enough to matter. Well it turned out the problem was the "new" 1964 dated replacement Cap, I jumped it, plugged it in and I knew I had found the problem when I heard the high voltage come on with a strong crackle! Junk cap, it only lasted 46 years. I'll probably go ahead and replace all the Electrolytics since one was bad and another was leaking. I may do the Selenium Rectifiers if the B+ isn't fully up to spec, I don't have a schematic for it though so I don't know what the spec is? |
| Audiokarma |
|
#6
|
||||
|
||||
|
Quote:
*Sams set 185, folder 10 (11/52). jr Last edited by jr_tech; 06-18-2016 at 10:03 PM. |
|
#7
|
||||
|
||||
|
I took the chassis to work today and replaced the bad cap, I don't know exactly what went bad in it, it wasn't dried out at all, in fact it was one of the wettest caps I've torn apart, probably because it's relatively new, probably the connector to the lug went bad is my guess.
I was going to put it back in tonight and try it but I forgot to bring the chassis home. Maybe I'll go ahead and restuff the last can, if I can find a 475 volt capacitor in my stash, it's only 56 years old so it really shouldn't be bad.
|
|
#8
|
||||
|
||||
|
Quote:
|
![]() |