The tripler came in today. It's funny that it came in an NTE box; but, is marked "Philips ECG" and has a date code of 0226 (I assume this means the 26th week of 2002) stamped on it. I knew that NTE bought ECG in the early 2000's; but, I figured they would have erased any ECG markings and restamped their parts as NTE. Having an '02 date code tells me that they are likely not making any more of these and are selling off what's on hand.
I also noticed that the new tripler is physically lighter than the old one and I hope that does not indicate an inferior quality part.
After installing the tripler and turning on the set, I heard two loud HV arcs. At that time, I was getting hot and had something else I had to do; so, I didn't get a chance to see where the arcing was coming from. It's very humid and I hope a simple cleaning of the HV anode (guess I should have done that to begin with) will solve the problem. I certainly hope the new tripler hasn't sprung a leak as I don't want the hassle of returning it and possibly getting another part that's just as bad.
I didn't have any RTV on hand; but, I had some HV putty and that's what I used to seal the input lead to the tripler. Also, I reattached the plastic insulator that covers the focus terminals on the tripler. It seems that most shops never bothered to replace the insulator or add any HV putty to the input lead. However, I'd like it to be put back together as close as it can be to how it was done originally.