Right, but I would think there might be at least a few DuMont tubes...
OK, there's more to tell. I have the set at my house now. Pulled the chassis and cleaned everything. Started by testing all of the tubes. 1 weak 6SN7, and a fried 5U4GB. The fried rectifier made me feel funny in the pit of my stomach. All other tubes are good, testing around 90-100% on my Sencore. No leakage either. The CRT checks about 98% and the needle slowly drops to 0 when I cut the filament power. YAY!! ![]() Here's the bad part. Started looking at the underside of the chassis and found a fried electrolytic first thing. This is probably what fried the 5U4. I pulled the spare 5U4 that I had installed, and using my variac, applied about 5 volts to the transformer. Instantly, my amp meter on the variac jumped to 2A. Not good. I looked around the chassis for obvious shorts, found nothing. In the 2 minutes that the variac was turned on with the chassis, the power tranny got very warm to the touch. I can smell it, too. I stopped testing. Im afraid I need a transformer. See the following pics... 1st pic: The bottom of the tranny that you cant see when the chassis is installed. 2nd pic: General chassis condition 3rd pic: The Offending Cap 4th pic: The source of the stinking burning smell. The smoke is rising from the hole the wires come through. Last edited by holmesuser01; 08-15-2010 at 10:10 PM. |