#1
|
||||
|
||||
|
Quote:
|
|
#2
|
|||
|
|||
|
swapped out some horz tubes (hot and driver) minor change. there were a couple out of spec resisotors the screen on the hot had a 47 that was 60+. it was in series with a 7 watt 4200ohm resistor. I am guessing the 47 was there to measure voltage drop to determine current since it gives a screen ma of 21 in the sams.
there was one cap that came off a winding from the fly that connected to the horz bias adj (which is a pot that goes to the HOT grid). I dont recall checking that cap. there were a couple other 5% resistors that were out 20% again in the grid circuit of the HOT. the coupling cap from the horz osc to the HOT is a .0047 but its a disc so I really doubt its a problem, but again, I may just shot gun the parts in the horz circuit when I pull the chassis. I will leave the 5% caps (the clear tube ones) in the horz osc tank circuit since the horz freq seems fine. Will just replace the screen and cathode bypass caps. there is a VDR in the bias circuit off the fly, but it has no specs so I cant check it. I assume this is used in the HV regulation, there is no shunt tube. |
|
#3
|
|||
|
|||
|
replaced a few out of spec resistors (not far but 20% on a 5% rated).
and a few disc caps in the horz osc circuit (mainly the coupling cap to the HOT). these disc tested "funny" on my cap tester, the eye would not open all the way and the edges were fuzzy, more so than what I have seen on other caps. I replaced with some good quality film caps, that were higher rated voltage. There was a 23pf 1kv on the damper plate to ground, just since I had the chassis out I replaced that one as well. |
|
#4
|
|||
|
|||
|
no effect at all, at least it still works.
Still under scanning. The adj calls for zero beam current, adj horz bias for 25.3kv. Not sure how to get to zero beam current, what I have been doing is turning brightness all the way down, screen drives all the way down, and CRT bias all the way down to get as dark a screen as possilbe. With the Horz bias turned fully CW I can get the cathode current to 220ma which is in line with the sams. I am reading this with a simpson 260 bypassed with a .1uf cap. when I turn up the brightness to a normal viewing setting (screen up and crt bias up) the cathode current goes up to about 320ma max (it varies with the signal). that just seems high to me. AND I still lack full horz sweep. voltage reading look good now that I am using my VTVM, the DMM was just not giving me good readings. There is a 4200 ohm 2watt resistor in the yoke (Y-107) but I cant imagine that being an issue. Next up will be the drived voltages to the HOT on the scope. |
|
#5
|
|||
|
|||
|
I read somewhere that you need to make sure your equip is accurate, well the VTVM was way off, I adj the calibraion.
I get about -40v on the HOT grid, should be -60 (yes it was that far off). My B+ voltages are off some but no more than 10 on the various B+ amounts. Considering that it should be able to fill out the raster at 110 and its short at 120 makes me feel its GOT to be the horz drive. I have tried mucho HOTs all about the same all NOS. So after much fiddling I will get the scope out, set it up (have to set the voltage so I can measure the P to P) and see whats going on. IF the grid drive is weak I will have to see why. I have tried half a dozen horz osc tubes, replaced all the coupling and bypass caps, and any out of spec resistors. The voltages all look right. the only thing I am not clear on is a 18k and 680pf 5% resistor in series that come off the plate of the horz osc. I assume this is some kind of wave shaping network. |
| Audiokarma |
|
#6
|
|||
|
|||
|
FIXED, AND i AM AN IDIOT
after consulting with some folks over at fun with tubes, I check the line voltage AT THE CHASSIS, turns out it was low, I still had the set on the variac and thought I had 117v at the chassis, wrong, voltage drop across the line/switch must have been doing me in. The orig problem of under scan was prob fixed when I replaced the osc driver tube, as this improved the scan width, but by then I had the set on the variac. |
|
#7
|
|||
|
|||
|
added some "active cooling" as a precaution on the fly, will monitor its effect on overall temps.
|
![]() |
| Thread Tools | |