#8
|
||||
|
||||
|
I'd check the solder connections under the degaussing thermistor (black cube; about 1/2" tall, near where the degaussing coil plugs into the board). VERY common to have that go cold, and it will energize for a picosecond in stead of the full second or so, which will actually magnetize and not demagnetize the tube.
Also it could be that the yoke has slipped due to a rubber wedge falling out. Check to see if the yoke pivots up & down or side to side. If that isn't it, you can try the others' suggestions, but I'd refrain from using the magnets if at all possible. If you do have to go that way (ONLY, ONLY needed when the tube's been dropped), you need to unplug the degaussing coil or the new magnets will be weakened after while. When I do the magnet trick as a last resort, I first set the purity as very best I can, which minimizes the magnet needs. The procedure is easy for someone who has done it, but I can't say it's so easy if you haven't. Definitely let us post a procedure for you if you will be fooling with the purity for your first time, or you might create a monster. Charles