Quote:
Originally Posted by colorfixer
Charles,
What is the official use of the grey plastic knob behind the deflection yoke. I have the same one on the PVM I posted about, and the manual quickly eludes to "dynamic purity".
|
Honestly I don't remember exactly, but I can look in the manual. I'm curious now. ON the later Sonys with the gray knob sticking rearward, it's a primary purity setting (to center the red bar in on the screen with the yoke pulled back). Probably the same here, but I'd hesitate to say unless I look it up. That little 330AB22 has electrostatic convergence through a second anode connector on the side of the neck, and it had a different setup procedure than the newer Trinitron tubes. I think the last time I did a setup on a 330AB22 had to be 25 years ago.