The magnets that were glued to the bell of the tube are additional purity magnets. They were installed at the factory. If you have them, after fixing the degaussing circuit, try placing them (one at a time) back where they were. It takes a bit of patience (and turning the air blue) to get them right.
I have used the two lead degauss themistor in place of the three lead. You have to find which two leads are AC. The third lead on Sony TV's go to AC neutral (most of them) and it gets the degauss out of the circuit quicker by heating it quicker. They do, as mentioned earlier, have problems with solder connections.
You may want to check the vertical IC on this set as it is prone also to bad connections underneath. If you have a ESR meter, check caps in vertical and in tuner power supply as well as standby and relay drive. They dry up and lose capacitance, blowing the vertical IC or making the set go nuts.
|