disconnect both of the green lead for the one side (not the convergence socket side) now the B+ load is about 8k with cold filaments (resistance reading at the output of the bridge rectifier). Was 24 ohms (yikes) with the transformer in circuit.
Gonna need some help locating a replacement, figured I would ask here, and give moyers a call. I need a part number. Its a CTC16XL, not sure what it is but its the xforer behind the HV cage. has grn/yellow (disconnect to find short to ground) grn (disconnect to find short to ground) blue red yellow then on the other side Orange blk/wht red/blk red/wht red/green green (this is connected to the chassis, I suspect it is a internal primary to secondary short causing the problem) Last edited by DaveWM; 10-19-2009 at 07:05 AM. |