Quote:
Originally Posted by Bill Cahill View Post
What about the selenium rectifiers?
They need replacing as well...
Bill Cahill
One of the dangers of posting progress; I was afraid someone would notice that.

The selenium rectifiers form a center-tapped full wave -125 VDC supply. There is a 39 ohm resistor in series with each rectifier. I believe they're there to limit in-rush current. They won't protect the transformer if the seleniums short.

The output of the supply is already fused. I intend to put a fuse in series with the 39 ohm resistors to protect the transformer.

On our original set we had to replace the seleniums once in its lifetime.

As long as the transformer is protected, I'm not worried. I have a lifetime supply of selenium rectifiers and if I have to change them every 5 years or so I don't have a problem with that. They're easy to get to and change.

I can't explain why I want to keep them in use anymore than I can explain why I want to watch a 60 year old TV. Maybe I just like the smell of garlic.

John
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 08:01 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.