Originally Posted by radio nut View Post
Well, I think I will be ok. I recapped the tester and now the guns check as follows. Blue holds at 920, green at 940 and red at 870. They now just sit there and do not change. I wonder now if the problem was caps starting to get weak and the extra transformer load of running three filaments at the same time on my tester.Now I will have to retest my b&w crts and see if they change from what I remember. Thanks for the tips, Doug
The color CRT was probably drawing 1.8 amps instead of 0.6 amps, but that shouldn't have cause a huge drift.

The electrolytics were probably increasing in leakage as they warmed up dropping the HV used for the emission test.

Congratulations on figuring it out and repairing your tester.

Did you get the set?

John