10MP4 test

Apparently triode CRTs are about as testable as electrostatic CRTs. None of the CRT analyzers that I'm aware of can test them.

I wanted to know the health of the 10MP4 in the Sylvania. I decided to measure the emission by using G1.

At least now I know that the CRT isn't dead. I measured a very high emission, but doing it this way collects most all of the electrons emitted from the cathode rather than the ones that go through the grid. The portion of the cathode that they would originate from could still be weak. You can read about why here http://www.sencore.com/uploads/files/RejuveCRTs.pdf

The Sylvania Technical Manual says that the G1 cutoff is measured by observing the extinction of the focused beam on the screen.

I plan on doing this. I'll need to supply the HV and also be very careful to start with G1 above the cutoff so as not to burn a hole in the screen. If it passes this test then it should be in pretty good shape.

Of course I could just test it in the chassis once I finish cleaning, recapping, and checking all of the resistors. But this is going to take a while and I'd like to know soon whether I need to get it rebuilt or not.

John
Reply With Quote
 


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 12:58 PM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.