![]() |
|
#6
|
||||
|
||||
|
Sorry for letting this thread drop for so long, but I wanted to get a
couple other projects started so I could put together a shopping list for the Big Hamfest (3 days long, 1 building of indoor swap tables, 2 buildings of commercial vendors, and loads of outdoor swap tables). Hamfests are great for finding parts for old equipment, but they only have one a year. Anyway, good news and bad news on my Beltron (model 2972-E.) Good news is that my Cleaning Lamps are OK. The #49 bulbs are 2.0 volts 60 mA and the filaments are hair-thin. I didn't see them until I held the bulbs against the fluorescent tube of my bench lamp. Bad news is that the Blue gun emission meter has an open coil, and the Green meter has a sticky pointer, but I can live with that. These are a common 0-1 mA rating, but are an odd size, made by Modutec (now Jewell Instruments), wider/shorter than common panel meters (sort of a 16:9 aspect ratio). I had no luck finding one at the hamfest, or at Skycraft Surplus (a local Industrial/Electronics surplus house.) It appears that Jewell/Modutec still make this style of meter, but their on-line catalog doesn't give the physical dimensions. The meters are mounted side-by-side on the Beltron, with no gaps between adjacent meters, so getting the right size meter is critical. It looks like I'll be PMing Refill233... Regarding the spark I got as I first plugged the unit in, the Beltron uses a voltage-doubler right off the AC line for the Restore circuit. There is no current limiting resistor ahead of the rectifier diodes, and there are two 160 uF electrolytics to charge up. I'm going to change the caps - the rubber seal on the output filter looks kind of pimply, and has 370 volts on a 350 V. rated cap, and add a 22 ohm wirewound resistor in series with the AC input to the doubler. Also, there is normally no load on this power supply, so the caps stay charged. There was still 40 volts left on one cap a day later. I'm going to add a 470 K 1 watt bleeder resistor across the output cap. I know this post is getting kind of long, but have any of the Beltron owners out there tried removing one of the Restore lamps and doing a rejuvenation? The two bulbs are in parallel with each other, and in series with the output of the voltage doubler, and serve to limit the current during rejuvenation. Taking one bulb out would cut the max. restore current in half, reducing the chance of damaging a CRT. Mike |
| Thread Tools | |
| Display Modes | |
|
|