What usually happens is the thermistor falls apart then the glowbar melts
down. Numbers I remember were FR922 & FRTV2 IIRC. And yes be sure the coil didnt get pinched !
73 Zeno
LFOD !

Quote:
Originally Posted by damen View Post
Similar RCA circuits used a 107191 thermistor (about the size of a nickel) and a 116534 or 114014 varistor ( the rubber coated looking one). Since this happened after the CRT was changed, be sure the degaussing coil isn't shorting out to the mounting hardware or you'll burn up the new parts.