#2
|
||||
|
||||
|
Have you checked the high value resistors on the reg tube? If it uses two 1.5M resistors they need to be a matched pair.
You may want to look into upping that B+, either by removing load from it or perhaps connecting the set to a variac and cranking the line voltage to the set a bit above what is coming out of the outlets. Remember conduction is determined mostly by the G-K voltage difference. Also if you have a service manual for that set it likely will tell you how to measure reg current off of resistors in the circuit...That info may help.
__________________
Tom C. Zenith: The quality stays in EVEN after the name falls off! What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4 |
|
|