Old 07-20-2016, 04:06 PM
BrianSummers's Avatar
BrianSummers BrianSummers is offline
TV Camera Museum Curator
 
Join Date: Jan 2009
Location: Surrey in the UK
Posts: 112
This is very odd.

The tube(s) and camera produce a good picture apart from the spot, so all tube voltages, scans, etc must be OK.

The newer Bi-Alkali IO works ok, no spot, resolution a bit down but o/wise OK.

The older soda glass target tubes have the spot which brings me back to my first thought that is is a tube fault, even thought several different tubes have been tried.

next step might be to try a known good tube tested in different camera, and to try your tubes in the other camera.

As an aside:-

I am told that IO tubes, and for that matter other high vacuum devices, have a failure mode were natural helium in the air "seeing the vacuum in the tube" goes though the glass as the helium is so small. The helium then accumulates in the tube.

If anyone can confirm or deny this I would be interested to hear what is said.
__________________
Regards Brian

Visit the Virtual Broadcast TV camera Museum
Reply With Quote
Audiokarma
 



Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off

Forum Jump


All times are GMT -5. The time now is 02:09 AM.



Powered by vBulletin® Version 3.8.4
Copyright ©2000 - 2026, Jelsoft Enterprises Ltd.
©Copyright 2012 VideoKarma.org, All rights reserved.