#2
|
||||
|
||||
|
To test the jug use the universal adapter & the "common"
settings ( dont remember what they were). Green & retrace could be H-GK short, tap neck wile running & see if it flashes. Can also hang a meter on GK & pull socket while running. Normal K voltage abt 100V - 130V, if low with socket on but normal off its the tube. Set can shut down with excessive beam current BUT it must warm up 1st. Can be caused by: Excessive G2 voltage loss of 200 V supply for the R,G, & B transistors. A dead shorted H-K may also. Sometimes these sets would come in with the power supply out. Fixed them, looked OK then a few weeks later back again. The CRT's arced & blew the supply. Most I saw bad were from low emission or drifting grey scale followed by shorts & arcs. It also affected cheap models more so I would guess they put a better grade in the high end sets ( they deny that). 73 Zeno
|
|
|