#14
|
|||
|
|||
|
Nowadays it's probably far less common to have electrolytics in series than it was 'back in the day'. The balancing resistors were a simple safeguard against unequal leakage values in the two caps. It wouldn't take much leakage difference to throw a higher voltage across one cap than the other, potentially exceeding its voltage rating.
|
|
|