looking very good now. Just have to check the HOT cathode current. Screen current is right on the nose at 18ma, grid voltage is -62v. I found two bad disk caps on was the coupler cap to the grid of the HOT and the other looked like a HOT screen decoupler, both brown disk. The grid cap would barely open the eye, the decoupler would open it about 1/2 way. Both were toasted somewhat by a large 5watt resistor (literally), they had brown burn spots on them. I replaced the grid cap with a 1kv dipped film cap and the bypass with a 630v .01 yellow tube cap. I am suprised the grid cap worked as well as it did. there is a .001 1kv disc cap off the plate of the horz discharge tube. Guess I should check it out as well. Its a 10% and I think it is related to the amplitude of the horz pulse from the discharge tube. I am still trying to get the PP up to 250v, its about 200v now.