#4
|
||||
|
||||
|
125 is kind of high, and those old sets don't really have any B+ regulation. It could overtax the flyback, I suppose. But you can get a step-down transformer, or a Bryan says, change the tap on your power transformer. A Variac is an expensive way to go, but it will work. I'd like to see my old sets running on about 110. Another old trick is to put a weak 5U4 in the set if it uses one, or whatever the B+ rectifier is if it's a tube
![]() Charles
__________________
Collecting & restoring TVs in Los Angeles since age 10 |
|
|