Quote:
Originally Posted by yagosaga
In the moment I have no time to work on the Philips K7. Xmas is coming and I have to prepare the Xmas services and a lot of presents for the family. Perhaps I found some time around midnight to make the measures at the luminance controls.
Tonight I have disassembled the Philips K7 and measured whether the brightness and color controls are grounded. They are not. I have grounded them, and then I got a picture. The Zener diode for the tuner regulation voltage I have changed last week. The only failure which remains is no contrast control. But this I will do in the next days.

A web page about the Faehnrich is ready, see

http://bs.cyty.com/menschen/e-etzold...h2441color.htm

And in the next days a web page about an East German experimental color monitor will go online. Due to server troubles I could only upload the photos of this monitor, which is appr. 1960 and fitted with a 21CYP22:

http://bs.cyty.com/menschen/e-etzold...arbmonitor.htm

Eckhard