i have repaired those on campus here,there is a service menu,and you have to have sony's software and cable to properly set up this monitor,someone may have tried this and gave up as it is kinda tricky,i have one of those on my desk at work,i will not let them give me a LCD monitor,i prefer the detail and sharpness of this monitor..my res is set at i think 1280x1024..its real sharp and nice,perfect gray scale,perfect geometry.
you may want to just check the yokes and wedges on the neck..
also you can not use a regular degaussing coil to degauss,you will in fact "MELT" the aperture grill..maybe some has done that..sony has a bulletin
warning about using deguassing coils on this series of fine mesh CRT's
good luck!..(my typing sucks this morning),I have only found shorted F.E.Ts,and on the ones that are left on "cooking" 24hrs bad capacitors..the chassis is kinda hard to remove and work on..if i remember you cant even set G2 unless you are in the service mode with their software,so you are very limited to any type of adjustments without sony's parallel cable..yeah it sucks..it hooks to your parallel port on ur computor..it was a $300.00 cable..with software,i had to dig it all out and look at it again

Last edited by wiseguy; 07-09-2006 at 02:34 PM.