Quote:
Originally Posted by zeno
C 524 most likely perp. Common to ALL brands.
Zeno
|
Hi Zeno. Thanks for the reply.
I replaced C524 already. I went through and checked all the lytics on this set a couple years ago, and everything in the H/V sections was way out and got replaced.
Taking it out and looking at it, I notice that the value is different from the service manual. Manual calls out 4.7, and I have a 10 in there.
Chances are I wouldn't do that unless a 10 came out of the board though. I tend to go with the PCB over literature.
But I guess someone else could have put it in there before I came around.
I can confirm that swapping C524 out for a brand new 4.7uf cap did absolutely nothing. Also tested to see if the HSTAT or purity rings had any effect and they do not. I was going to test the other rings, but I doubt they will have any effect, and I'm getting tired. Can get back to it tomorrow.