Most of the eye type capacitor testers require lifting one leg for testing (and all do if testing DC leakage). There were a few that used RF to check capacitance that could do a capacitance (but not an accurate leakage test) in circuit.
Orange drops and their brown and maroon cousins can develop leakage but it's rare and typically only ones installed on boards next to hot tubes.
If you take one that tests bad in circuit lift a leg and retest you'll probably find it's ok with a leg lifted... Some testers are sensitive to which lead of the tester goes to the lifted terminal and will display false leakage even with one leg lifted....My Heathkit C3 will display leakage regardless of which lead is hooked to the lifted end of the cap if the TV/radio/whatever the cap is part of is connected to anything that's plugged in.
__________________
Tom C.

Zenith: The quality stays in EVEN after the name falls off!
What I want. --> http://www.videokarma.org/showpost.p...62&postcount=4