View Single Post
  #3  
Old 09-03-2024, 04:56 PM
Claustrofob Claustrofob is offline
VideoKarma Member
 
Join Date: Aug 2024
Location: Gothenburg, Sweden
Posts: 10
Quote:
Originally Posted by Alex KL-1 View Post
Is possible to have simply the wrong adjusted parameters but, is good to check some parts in the E-W circuit and the HOT, such as:
2401 (ESR included)
2465
2462 and the ones in parallel
Thank you for helping!

The SAM (or service menu) doesn’t offer any adjustment for the E/W parameters, they’re simple not in the menu in this model. I have the key combination to access it and I’ve checked.

2401 - ESR is good
2465 - No shorts and measures 9nF
2462/2466/2467 - My model have 2466 only and it measures around 10nF.

Im not exactly sure how to measure film capacitors. I desolder them, discharge them and testing them in capacitance mode on my multimeter and also on my LCR-T4 meter. I have a ESR meter but these are film capacitors?
I also tested them on ohms mode on the multimeter and I can se that they charge up and becomes OL. The 2465 charges up really fast so I almost thought it was open.

Any tips on what to do next?
Reply With Quote