By convention use the steel chassis for ground ( - or black lead).
Newer sets may have several ground points. Voltage is measured
at the Hoz out tube G-1 (6LB6 ? ). If the voltage in NOT very
negative ( @ -70 to - 90 VDC ) it will eat the H out & in some cases
melt it ! So keep testing under 1 mn til you get a raster.
You can measure from the top, you just need to count the pins CCW.
Pin out is on any data sheet for the tube.