It has a picture but still needs a lot of work.
Interesting was that when I applied power the first time, I got no raster. I stuck an NE-2 neon bulb next to the HO transformer and it glowed. I thought that the horizontal must be oscillating. But no high voltage. Hmmm, how can that be?
When I had an outside maintenance crew with the phone company, I always told the guys to not overlook the possibility of it being the obvious.
The 1B3 was original and I have never had one fail. Could it be? I have a ton of them because they never go bad. It did. Apparently the horizontal feedback ring ring around the envelope placed too much stress on it and it fractured. A new 1B3 fixed that.
|