The neck is 29mm.

I've used my cheepie component IDer, the horiz. coil measured .9 ohm and .13 mH.

The initial problem was the monitor seemed dead. B+ from the switching supply was getting pulled down from 83v to 35v. HOT was getting... hot. Removed the HOT and tested it, seemed fine with a meter transistor check. Unplug the horiz coil and the monitor is much happier. B+ is normal. No HV though.

FWIW, here's a view of the chassis on this beastie:



You can see some of the glue which has turned brown / conductive. I've removed it since taking this photo.

Higher resolution version of that photo, and the back side of the PCB here: http://compu85.net/stuff/xerox/6085/monitor/

-J
Attached Images
File Type: jpg Screen Shot 2023-06-05 at 5.48.22 PM.jpg (139.3 KB, 82 views)

Last edited by compu_85; 06-05-2023 at 08:15 PM.