Quote:
Originally Posted by jr_tech
“R219 is very easy to reach and add a cap to, however the point of L56 and the bridge wont be so easy to reach”
Why not add the 82 uf caps downstream, at the circuits that are supplied by the 400 and 390 A sources?
jr,
|
yes, I do have access to R112, the only point that seems to be hooked to 400v can't find the 2nd that is mentioned on the distro chart, won't putting in the 82s w/o being able to reach in and unhook the old C1 cause undue stress on the diodes? or will the termistor dampen this? this was the only reason I was thinking of using 33uf.