As I understand it the HV reg monitors the B+ boost voltage (boost voltage is a good indication of HV level, loading and sweep width) and changes bias on the H output tube to increase conduction if boost is low and decrease conduction if boost is high. Basically if boost indicates more energy is needed it tells the H output to give more energy to the flyback, and vice versa.
It's gentler on flybacks because instead of giving them constant high energy then loading the output down as needed the fly can loaf along with less drive when it doesn't need max drive levels to work best.
Been a while since I last read up on operation of this and it's late so take that with a grain of salt.
Last time I had to troubleshoot one of these sets for an HV issue the yoke had corroded and it's phenolic was disintegrating and it took me a LONG time to trace the low HV problem to that especially since the set would be okay for 5-15 minutes before going dark.
|