Quote:
Originally Posted by init4fun
That the open circuit is between the last pin and whatever wiring it normally uses to complete the circuit .... 
|
Correct, the last tube in the string, the ratio detector 6AL5 was open. I replaced it and brought up the variac and dim bulb and it started red plating. The filament didn't burn up so the tube might be OK but there's something else going on. All of this started when I powered it up a few weeks ago and the 3 ohm resistor between the filaments of the second to last tube, the sound IF 6AU6 and the 6AL5, the last tube in the string burned up. I replaced it and had nothing since but that was because of the open 6AL5. With a good 6AL5 in the last socket, I'm back to the same resistor/tube frying problem all of this started with.