Quote:
Originally Posted by Mangie
You recon that orange safety cap needs replaced? I just so happen to have the exact same one on hand new in the package that was part of a tube sale not long ago
|
If it was an earlier chassis with a white one I would change it BEFORE doing
anything else. But yours is OK. This is the process with the white one:
Cap opens but does NOT disable the HV. ( was designed to ).
HV goes up to abt 40 KV & set starts arcing.
Arcing blows vert module & DC gets on the vert yoke winding.
Winding heats up & cuts the neck off the CRT
Same thing happend to some Magnavox sets too.
Set looks very strong so should run near new when done.