Not sure where we are now but.......
To measure H Out current you need to open the cathode pin from GND
and put a ampmeter in series with it. Depending on the meter you should
decouple the cathode with a cap to smooth it out. It goes in // with the
meter.
SAMS has instructions on value of cap & procedure.
Adjusting the H. osc ( hold) will effect the G-1 negative voltage.
Keep in mind the whole thing by design needs to be in resonance
to be happy. If the G-1 is in spec you are good till that point.
A freq counter or scope can show you if its at 15,750.
AGC as a rule goes to the RF amp & IF # 1 & 2.
SAMS will show AGC voltages either with or without a strong signal
or both ways. AGC problems are VERY rare, I cant really remember
many in 40 yrs & tens of thousands of sets.
73 Zeno

LFOD !