Ok there was a resistor pin 7 of 6cg7 to pin 1 of v6 which is the 190v source the resistor is a 560k it checked.800k so I changed it and I felt it and was warm so I disconnected one leg and the hv came back and it’s stable at -45 so if I put the resistor back the voltage pulls down so there maybe a problem at v10.I’m thinking the 56pf cap may be shorted since it’s tied directly to ground and the 56k resistor is 61k.
Last edited by timmy; 09-20-2022 at 02:50 PM.
|