One thing bothers me. Go back to @1975 with this set. It comes in
no snd / no raster. Something finally killed it No mater how many
other problems it has, probably many, one thing should bring it back
to just running.
After a quick check to see if the PS is up & running go to the H sweep, maybe
the H out tube is dead. We did not pull a Sams to be sure the voltages were
within 3%. At that point the jug was evaluated ( by eye) & it went from
there. SO IMHO only get the raster back & not worry so much about the
crazy PS voltages. You only need a few voltages to make the H osc & H out run even with lowish B+. You may have bad width but it will give you a raster.
BTW Never blindly trust Sams or the OEM manual !
BTW #2 A good meter is a lifetime investment. Since the 70's I have
had a Hickock ( bench meter) a Beckman & a few flukes. They all still run
& are very hard to accadently get fried. I also got both my sons Flukes
for xmas.
BTW#3 Never blindly trust a tube or CRT checker we NEVER used a tube
checker but had a TOTL B&K for customers & it was a big profit center !
enuf fer now
Zeno

LFOD !