Quote:
Originally Posted by Electronic M
Once you have a good CRT change the bad HV wire properly. When that insulation kludge fails on you again a few weeks or months down the road you'll wish you had replaced the wire.
|
When the high voltage rectifier winding arced through, I used to cut out the wire and used an EDI solid-tube which was a solid-state replacement for a 3A3/3DB3 or a 3AT2, depending on the set. It was especially important on a Zenith that used resistance wire for the winding.
RCA's seldom needed it because the flyback was replaced before.