Quote:
Originally Posted by ppppenguin
Usual to plug the radio etc under test into the isolating transformer.
The output of the transformer should float. Neither end grounded.
A GFCI (RCD on this side of The Pond) is of no use on the output side of an isolating transformer. Apart from the rare and special case of a failure of the transfomer itself it doesn't give any extra protection on the input side either.
If working on a hot chassis (live chassis in UK/Europe) set an isolating transformer is essential if you want to connect testgear to the set. Otherwise you can make sure the chassis is conencted to neutral and use a GFCI/RCD.
|
I just worked on an Emerson portable radio that has a hot chassis yesterday!
I have several sizes of isolation transformers, but I seldom use them. Old habits die hard. Our low voltage, 120 volts is a lot less hazardless.
As an electrician, I believe in GFCI's and all the receptacles that I use when repairing are GFCI equipped, either receptacle or breaker.