Some additional notes to Zeno's. I believe the hybrid chassis numbers up to B line included both tube count and transistor count. For example my 15Y6C15 IIRC has 15 tubes and 6 transistors.
Zenith didn't want the set to work without the HV regulator installed so they wired the damper and reg heaters in series. However there were 2 different heater current HV regs and 2 different heater current dampers....If you didn't use a pair with matched heater current one tube wouldn't warm up properly and the other would have excessive heater voltage...I don't know how it effected the HV but it obviously wouldn't be good.
Your boost is actually 820 since the 400V rail is only measuring 360V.
IIRC it's possible to run one of these sets without the HV regulator if you use clip leads to connect only the heater of the regulator. HV will be as high as it can be that way but if you need a go/no-go on the flyback that is a way to get it.
I have a 20CC50 that years ago I wanted to fix but didn't have the IIRC one and only HV reg it needed. I think I briefly ran it like that to make sure the fly was OK, then I figured out I could add or swap a wire for a cathode, plate or grid to make a 6HV5 work in it.
|