Quote:
Originally Posted by Electronic M
Questions 1 and 2. If you have the back open change those white caps! They can fail at the drop of a hat even if they test good, and when they fail they spray conductive foil everywhere that can short other stuff and increase collateral damage.
You can buy the spade end crimp connectors from any hardware store. What I'd do is strip the one wire and solder on a crimp connector.
Last question. Most makes used the same cathodes for everything from 5" to 27" CRTs. That cathode has a limited amount of electrons it can emit. The bigger the screen the more emission it needs for a given brightness level, thus smaller CRTs last longer and can work better with a weak CRT.
|
I will use calipers to measure the dimensions of the white caps and order polymer film type capacitors as replacements.
I went ahead and replaced all of the vacuum tubes (except the CRT), with new old stock tubes. However, I was not able to replace the ultor rectifier in the high voltage cage, because the top cap was very tight and I worried I might damage it when removing it. This is my first tube based ultor rectifier.
Question #8: Any tips for removing the top cap without damaging it?
I also cleaned the glass on the triode section of the CRT, so you can now see inside it. It is a very large electron gun for such a small CRT. Its circumference is as big as the horizontal output tube, which is also a very wide vacuum tube.