Quote:
Originally Posted by JohnCT
You can't check capacitors that way....
Equivalent Series Resistance
|
Or "ESR". You need an ESR meter and study up on how to use one. It's pretty simple really. Capacitors dry out and the internal resistance goes up. Easy to measure in-circuit (with the power OFF). I'd almost bet money you would find the culprit electrolytic with one.