View Single Post
  #14  
Old 12-13-2020, 12:34 PM
JohnCT's Avatar
JohnCT JohnCT is offline
VideoKarma Member
 
Join Date: Jan 2020
Posts: 749
Quote:
Originally Posted by Jeffhs View Post

I am nothing short of amazed there are no safeguards against sweep failure in SS televisions; in fact, I strongly believe there should be some sort of protection scheme, even one as simple as a fuse, to shut down the entire sweep system (both sweeps) in the event of failure of either sweep circuit.
Most SS TVs made from the late 90s on did shut down the TV with loss of either sweep. Once projection TVs came into popular production, many CRT TVs used the same jungle and uPc ICs as the PTVs did, so they shut down because the ICs were designed with PTVs in mind.

The Zenith chassis series after yours will shut down and require an AC unplug after a vertical IC failure.

Regarding shutdown circuits, there is no safety hazard for loss of sweep, which is why there was never any gov mandated protection. HV runaway is a different story, which is why all SS TVs from the mid 70s and on had a rudimentary protection scheme of some sort to mitigate runaway HV. A lot of TVs wouldn't shut down, but would swing the horiz osc off which would lower the HV. Later ones shut the chassis down completely.

Projection TVs will destroy all CRTs in a split second with loss of either sweep, so designing shutdown circuitry was critical for warranty considerations, not safety. RCA in fact sent a negative voltage to the CRT sockets which did nothing until there was a loss of sweep. In that event, the -200v was immediately applied slamming the tube off faster than the shutdown circuit would allow a normal voltage decay.

John
Reply With Quote