Quote:
Originally Posted by DavGoodlin
....the VA-48 tells me the HOT is bad though it measure 600 ohms..
|
The resistance between the plate cap of the horiz out and the HV rectifier is the first quick test when checking the fly, but if it passes that test, there's still the possibility of a shorted turn. An ohmeter treats coils like resistors and a single shorted turn renders a coil useless and won't be discernible with an ohmeter. The VA48 will ferret out those with shorted turns.