Quote:
Originally Posted by BandDirector
This is after tube swapping. There is a lot of buzz in the volume.
|
Very sweep is running at twice frequency.
The short is more likely to have fried a resistor... Especially if you used all 630V caps and B+ is no bigger than 450V.
If you shorted the height/Lin pots you especially want to check resistors in the Bą boost supply if this set uses boost to feed the vertical.
Boost is a circuit that recovers energy from the flyback and uses that energy to supply high voltage ~1000VDC to the vertical and sometimes CRT G2.