The tiny magnetic head gap in a VCR has a N/S alignment relative to the E/W sideways mounting/spinning of the full head. A horizontal horseshoe arrangement if you will. It can be clogged by any number of problems, fibers, dirt, shedding oxide. The problem is in the pollution in the gap. Wiring is a separate problem.

The trick is to not induce more problems with fibers, paper dust, or others.

Here is where I use many years of clearing clogged heads first with problems with 2" quad tapes going south on one head on air. Just press your fingernail against the spinning head The ultimate crude fix in the day. Usually worked. You cleared the problem in the gap.

With VHS I have and continue to use a gentle N/S rub across the head gap with my finger dipped in Isopropyl or similar. E/W sometimes works.

I wet my fingertip and turn the drum until I find the heads (all of them) and gently rub it N/S. You are not going to snap a head off with gentle fingers. Then move on to the next head. It is as gentle as anything I can think of and addresses the N/S problem across the gap where all the problems and cotton fibers lie.
__________________
“Once you eliminate the impossible...whatever remains, no matter how improbable, must be the truth." Sherlock Holmes.

Last edited by Dave A; 04-29-2020 at 07:48 PM. Reason: text